Sometimes you have to be 'trades' man enough to know when you are beaten

2/10/2023

1 Comment

 
The job of an electrician can be quite physically demanding. Sometimes, you have to be tradesman enough to know when you are beaten. The ladder is a tradesman's constant companion, and there will be times when a ladder is not up to the job.

I have been working for a client who purchased a water mill. The place and location are stunning; as you can imagine, plenty of water runs alongside. The property needed an electrical upgrade, and while this was the initial first step, the client had bigger plans! Plans to utilise the watermill to generate electricity. With a supply already coming into the property from an electrical supplier, their role in this project stopped at the pole. The installers of the generator at the mill also meant that their responsibility stopped at their generator. The bit in between... the bit to connect the watermill to the house and the house to outbuildings, became the responsibility of an electrician, and as I am already part of the project, that meant me!
I was responsible for connecting the 25mm 5core cable from the first fuseboard in the outbuilding and then running the cable outside to a resting position on the electricity pole. From the electricity pole with tight tension and special pigtail bolts, secure the cable to the house and into the second fuseboard. From the second fuseboard, back out from another corner of the house, with tight tension, connect the cable to another pigtail bolt and into the watermill, ready to connect to the third fuseboard. The hydro team had already installed their generator. Once all the cable was in place, the hydro team could connect to the final fuseboard to allow electricity to feed back through the complete electrical installation. I have been informed by the client that electricity is now being generated!

Unfortunately, 25mm 5core cable is not malleable, especially during these cold winter months. Although I had sourced winches and pulleys to help manoeuvre the cable, there came a point quite early on in this section of the project where one man and a ladder were not going to cut the mustard.

At the end of November, on a cold and foggy morning, accompanied by my wife, we set off for the first part of the installation, connecting the 25mm 5core cable from the fuseboard in the outbuilding, up into the loft space, outside and up to the electricity pole. The cable is hefty, so imagine carrying this up the ladder each time to correctly connect the cable under the eaves outside. On second thoughts, please don't imagine; it was difficult and took a lot of time and energy. Unfortunately, this resulted in medical attention, which I won't elaborate on here. So wife's wise words, "get down off that ladder now! and we will need to rethink this and provide a more efficient and effective safe solution."  
And that is what we did. We found an efficient and effective safe solution by contacting Steve Beck, the Cherry Picker Man, who gave us a price agreeable to the client. In addition, I reworked my hours, which allowed for this expense without additional funds to the client. And so, on another freezing cold day mid-January, Steve and I met at the client's property and successfully completed the mission together. All done in a day!

I, my tools and the cable were safely housed in the cherry picker basket and escorted to the correct heights at the various buildings so I could safely and efficiently carry out my electrical duties.
I now know my physical limitations. I also now appreciate my wife's wise words, "safety and efficiency" are always the order of the day. Sometimes, and I am sure other trades are the same, years of experience means you take a few risks because you know what you are capable of. But there are times when the risk is not worth compromising life and limb. This project had given me some sleepless nights, and once we knew the Cherry Picker Man was on board, the worry, which was as heavy as the 25mm 5core cable, also became lighter!

Now that the external side of this project is complete, my work continues inside.

For more information on how the Cherry Picker Man, Steve Beck can help you visit his website and or Facebook page.

And as always, I am here to provide safe electrics to every home!   
1 Comment

Consuel and Certificate of Conformity: when, why and how

3/1/2020

3 Comments

 
Picture
What is Consuel

Consuel is the acronym for Comité National pour la Sécurité des Usagers de l’Électricité. They are responsible for the control of an electrical installation whether that installation is carried out by the home owner or by a qualified electrician. It is also the name of the certificate of conformity. The certificate of conformity is compulsory when looking to connect with an energy supplier. It guarantees the safety of the installation and for those living in the dwelling. The most commonly used form is the yellow one for domestic electrical installations.

What properties does it apply to?

A certificate of conformity is required where there is no supply at the property. *
For example you have purchased a barn and you are converting it to a domestic dwelling.

The property is a new build domestic dwelling

A certificate of conformity is not required if you have purchased an older property and there is an existing supply coming in. Although it is prudent to make sure the electrics are safe and compliant and the incoming supply is sufficient for your needs.

* If you are renovating a property where there is no supply, you can request a temporary meter. This will be available to you right up to the point of connecting your supply to the energy supplier. And is dependant on a certificate of conformity. You cannot request connection without it.


What does it mean to the homeowner?

If you choose to do your own electrical installation you, as the homeowner, apply for the certificate of conformity. It is not unusual for homeowners to do their own installation. However, it must conform to NFC15-100 standard. And when you are ready to apply for your certificate of conformity it will be via consuel.com and your application will be made as a particulier. An inspector from the Consuel will visit your premises and if compliant you will be issued with certificate of conformity. If it is not compliant you will need to correct the work and request a new visit.

If a qualified electrician does the installation the work is installed to NFC15-100 standard and when ready to apply for certificate of conformity he visits consuel.com and applies via the professionnel space. As the qualified electrician is required to be aware of the normes and will no doubt have a number of applications submitted it is likely that an inspection is not required and the certificate of conformity issued.

Please note that a qualified electrician will not submit a request through his professionel space for an indiviudal. If an individual has carried out the electrical installation themselves, the request for certificate of conformity must be made by the individual. The professional tradesman’s insurance is to insure his work only, not the work of others.

What is the process

  • Once your installation is ready an application is requested for the yellow form via the Consuel site [consuel.com]. You can do this either digitally online or via the paper method. You will be asked to create an account and supply information.
  • Once the yellow form is submitted allow for about 20 days before an inspector will visit your dwelling to assess the install.
  • If the installation has no anomalies the Inspector will affix his visa to the certificate. You will receive this either by post or it is downloadable via the site and your personal space, depending on what you have opted for. You will need this certificate to present to your energy supplier for connection.
  • If any anomalies have been identified you will need to put these right and request a new visit. A certificate of conformity will not be granted until the Inspector is satisfied that the installation complies.

​If in doubt always speak to a qualified electrician 

3 Comments

Have you got enough protection?

1/30/2020

3 Comments

 
If like many of my customers your fuseboard has been upgraded, it will consist of rows of circuit breakers. Each row will be protected by an RCD which will be the larger size switch, normally at the start of the row on the left. An RCD is a Residual Current Device use for protection/earth  [as per picture below]

​

Picture
Next door to the fuseboard is an independent box the main switch, the property of your energy supplier – see picture with the words 30/45/60A and in a glass window, ever so small, you will see a number either 30, 45 or 60A and this tells you the amount of supply you have coming into your premises. [as per picture below]
​
40A RCD serves up to 4 breakers
63A RCD serves up to 8 breakers


Picture
Over many months I have received calls from customers who have experienced regular tripping of the RCD which would suggest that an upgrade from 40 to 63A is recommended. And on subsequent follow ups, this has often been the case.  As always, if in doubt, speak to a qualified electrician.
3 Comments

Lot 20 new EU Directive for electric heating 2018

2/11/2018

1 Comment

 
Picture
As of 1st January 2018 new energy efficiency regulations regarding electric heating have been introduced. Lot 20 legislation states that space heaters for sale in the EU will need to adhere to these new laws or be axed.

Lot 20 is a piece of legislation that most people have not heard of but massively effects the manner in which electric heaters are produced. It has been introduced by the European Ecodesign Directive which governs all energy using products including lighting, washing machines, vacuum cleaners to gas boilers and solid fuel burners. These are split into several 'lots' and Lot 20 applies to local space heaters including storage heaters, electric radiators, radiant heaters and underfloor heating to name a few.

Many heaters now include smart technology to help reduce energy consumption, electronic time and temperature controls, open window sensing technology, predictive start functionality and remote app based control. Old non compliant radiators can still be sold after 1st January 2018 provided they were manufactured before this date.

The use of electric heaters are still popular for home owners in France, French and non French alike. So for the home owner if you are thinking of upgrading or adding electrical heating to your home, use this information to help guide you, so that you are aware of what the legislation is and the choices that are available to you.  


Picture
I have certainly seen new and efficient products on my travels and have installed these sleek looking glass radiant panels.
New products to the market will have price increases but the long term use of them, should see consumption being used effectively and therefore not compromise your bills.

For more information regarding this directive, please visit this English site https://www.lot20.co.uk/
1 Comment

Rewires to remember

9/11/2017

0 Comments

 
It has been an exceptionally busy time for me this year right from January 2nd to Monday 14th August, when I took a well earned rest for a couple of weeks. The first time in 5 years! A proper break.

As well as remedying electrical problems for existing customers and tending to electrical additions for many, I have also been busy with rewires. Three in particular have kept me busy this year and each have been different.

Sauze Vaussais - Dept 79
I was particularly delighted to work on a rewire on my door step. The clients had purchased a property which needed a complete renovation. They had purposefully purchased something that they could put their own personal stamp on and incorporate some cool gadgetry for their minimalist but functional home.
After completely gutting the property builders set to work in reconfiguring the home exactly to the clients wishes. With me doing my bit to include lighting of stairwell, zonal lighting in the lounge, dining and kitchen areas. All controlled by a panel in the main lounge/diner. Even the external lighting is controlled by a separate remote system either by a hand held fob or wall panel. Continuing on, high ceilings meant the installation of velux window blind which are controlled by hand held remote. I love it when clients want to explore creative lighting options in their home fused with advanced control.   

Here's what the client had to say about my work:
​“Nothing is too much trouble for Paul! Having installed the complete wiring from scratch for our renovation he was happy to come back and do the smaller jobs like garden lighting and even making the trip to add a single socket in one room. Paul clearly knows exactly what he is doing and ensures that everything conforms to the French regulations and standards. He worked well with the other builders on site and fitted into their schedules as much as he possibly could. We are delighted with the results.”
Champagne Mouton - Dept 16
June was dedicated to a 4 week rewire at Champagne Mouton. A lovely town house with great history and a real depth of character. I had been recommended by Andrew Johnson/Karen Jones in Ruffec for some electrical works to the kitchen. Having visited the property so that I could prepare my devis, it was clear that the main fuseboard and earthing was a little unsuitable. As safe electrics is paramount I brought it to their attention immediately. They were aware that the system was old and as they were planning to do a number of aesthetic works themselves to the property, they invited me to present a devis for a rewire. Once accepted, a new fuseboard replaced the old with clear identification of the various zones, with surface mounted trunking and surface mounted sockets and switches.
​
Here's what clients had to say about my work:
Thank you Paul, for the great job you have done rewiring our house.
We were impressed by how hard you work, your pleasant attitude and friendly disposition.
We would highly recommend you to other people who need electrical work done.

Fontenille - Dept 79
After the 4 week rewire in Champagne Mouton my next job was a 3 week rewire in Fontenille. Client was keen for a rewire of an old non compliant installation before commencing with internal decoration. We had several meet ups before deciding on final works. Trust was of paramount importance for this client, living solo. It is a huge undertaking for many people when they live in their homes, fixtures and fittings are in their place, everything is how they want it to be. Invite a few tradesmen and suddenly dust sheets, moving of furniture can be pretty disruptive to their day to day lives. The house was originally 2 separate houses and electrical works included 2 fuseboards to provide adequate supply and circuits for a bigger property, with an additional fuseboard in the garage to feed circuits in the garage and provide overall protection. Circuits were rewired and all 2 pin sockets replaced to comply.

Here's what client had to say about my work:  
I had Paul Wilkins do a complete rewire on my house, it was a complicated job & he advised me accordingly.He was extremely tolerant of my need to understand the process & my changing my mind. (A woman’s prerogative). He was always very punctual (I could set my watch by him) and he always had cheerful smile (despite my constant questions). I am thrilled with the results & have no reservation to recommend him to anyone.
0 Comments

Customers want peace of mind when dealing with trades in France

2/6/2017

0 Comments

 
Picture
When customers are not living in France full time and have commissioned work to be carried out they need peace of mind that the job is going to be done in their absence.

I have recently finished an electrical job at L'Isle Jourdain, Vienne [86] for a client who divides time between France and the UK. I initially was asked to provide a devis for the work via a team of builders who I have worked with before and submitted the devis to the client which was accepted shortly after submitting. The work commenced with the client the other side of the Channel and was more than happy for me to liaise with her designated key holder along with other trades who were on site.

The property was a typical older French property which didn't not comply to current NF normes. When clients are not here full time I take photos of the work that I am doing and then share to either dropbox or google drive so that they can see exactly what I have done, as per the devis submitted. Regular updates help me keep in mind any considerations or suggestions I need to make as the job goes along.

This particular job continued right up to Christmas and the New Year. With other works continuing, such as installation of the heating system, it meant working on site was cold, as working alongside a plumber who was installing the central heating system. A lovely job to do with no real challenges other than the fact initially it was a 3 phase installation but when EDF came along for some strange reason they had made it single phase, so modifications had to be made to accommodate single phase installation.

The job was completed on time and with the detailed photographic work, the client was more than happy with the results. I shall look forward to returning in the Spring to work on new recommendations that I have made. ​

Paul Wilkins
You might want to visit
Testimonials 
0 Comments

Winter Round up 2016 

1/11/2017

0 Comments

 
Picture
image courtesy of pixabay.com
Despite Brexit I was fortunate enough to benefit from a number of house purchasers who made contact with me to provide electrical devis. Subsequently the autumn and winter months for Paul Wilkins Electricien was extremely busy in the Deux Sevres and departments 16 and 86 bordering.
As with many older French properties, many lack earthing which predominantly helps make the electrical installation safer, along with updates to fuseboards and circuits to service clients needs and appliances in their homes.
I closed 2016 with a couple of ongoing rewires for habitats where clients have gone all out in redesigning their homes and have enjoyed working with many building teams [it can be lonely working on your own, but my new Bosch 360 Professional PowerBox Jobsite Radio will keep me company]. Plus enquiries where clients want to concentrate on outside garden lighting, and entertaining areas where outbuildings are being turned into bars.

Here's to another successful year of keeping homes electrically safe,
​
Paul Wilkins


0 Comments

Anyone for bubbles?

8/1/2016

1 Comment

 
Hot tubs are fast becoming increasingly popular for owners of French homes. Whether it be an inflatable or portable system for 2-4 people or something that is permanent for up to 8 people with music and lighting systems integrated.
​
Many customers who have them say they would not be without it.  Have to say, if I were to choose between a swimming pool or a hot tub, it would be a hot tub for me! 

Picture
When it comes to the power supply you need to make sure you have plenty of power to run your hot tub and be aware of the safety protection required. A fixed hot tub usually requires a 32A dedicated supply, and must be RCD protected. I would also recommend a cut off switch be accessed within close proximity of the hot tub.
Picture
The inflatable hot tubs can be plugged into normal socket [depending on power rating], again must have RCD protection.
​
Over the last 18months I have been called upon to help with the installation of both inflatable and permanent hot tubs, and will be only too pleased to assist if this relaxing feature is something you want for your home - paul@paulwilkinselectricien.com
1 Comment

Useful guide to making sure you work with registered and insured trades in your French home

7/21/2016

0 Comments

 
Picture
As a registered and insured tradesman myself, I hear lots of horror stories from customers and potential customers who have experienced unpleasant circumstances. As a registered and insured tradesman I have no qualms in presenting any details to any customer. For me, I want a customer to feel that they can do business with me that is legal.

When you are seeking the services of a tradesman the likelihood is that you will ask for recommendations from people that you know or from your local magazine. Don't take these at face value. There are a number of obligations that you need to consider before anyone crosses your threshold and commences work, as there are serious implications for the homeowner should you choose to use unregistered or uninsured trades people on your premises.

There are a number of sites that you can visit to check siret numbers :
https://www.infogreffe.com/societes/
http://www.manageo.fr/

http://www.societe.com/

However, please note that these sites will only provide details of the main and primary activity and not any subsequent activities.  
If in doubt, feel free to call your local Chambre de Metier and ask them to verify what they are registered as, or enquire with your local Mairie.

Don't be afraid to ask to see attestation or confirmation of the relevant insurances attributed to trades. Who is the insurance with? Are payments up to date? We all know France loves a law and insurance. Each activity needs to have the corresponding insurance. Insurance for one activity does not cover for all.  Please note that there is difference between public liability insurance and decennale insurance and some trades are required to have both. If you have doubts, eliminate them from your research.

Artisan tradesman are required to have decennale insurance and a carte professionnelle – this provides confidence to a potential customer that they have had their qualifications verified by the Chambre de Metier and are appropriately insured. Plus artisan tradesmen are not allowed to register additional activities. For example as a registered artisan electrician you won't see me offering to cut your grass.

Devis and factures will need to show siret number and insurance details, these are recent requirements, so if you don't see this on any paperwork, again feel free to eliminate from your research.

Devis should be clear and set out exactly what will be done. Do not sign a devis until you are happy that everything you want done is included. There should be no hidden surprises between devis and facture. Be clear about when works are to commence, particularly when there are a number of trades involved.

A reputable tradesman will ask for a deposit or materials to be paid.

A reputable tradesman will clearly state how future payments are to be made.

A reputable tradesman will not insist on being paid cash.

A reputable tradesman will happily give you references of customers that you can contact if you request to do so.

A reputable tradesman will have more than just a mobile number to be contacted on. 

It is not unusual to seek 2 or 3 devis and a reputable tradesman will be aware of that. You as a customer should be able to ask questions and feel confident about who you are dealing with, as ultimately they will be working in your home and you will be paying them. So any doubts or concerns you have eliminate them from your research.

Always work with a reputable tradesman, there are serious implications as a home owner should an unregistered or uninsured or not appropriately insured tradesman be working in your home. Should an accident or death take place in your home, you as the home owner will bear some responsibility.

​Should you wish to sell your house you may be asked by the Notaire to provide invoices for major works that have been carried out within a certain timespan. If you are unable to do this, you may find yourself footing a bill should something untoward happen in the future once your home is sold.


0 Comments

Nanny will be pleased with the new milking parlour! 

6/27/2016

0 Comments

 
Picture
Much of my work is rewires and renovations for domestic properties in rural France, and appreciate it when I get an opportunity to do electrical work at non-domestic premises, especially a milking parlour.

Very recently I was asked to take a look at connecting a 3 phase milking machine for local enterprise, Noah's Ark Farm based in Bouin. I made a visit before commencing works to see a huge carefully dis-assembled milking machine with its wiring loom completely intact. More than happy to undertake the work so returned the following week to find the machine re-assembled and mounted ready for re-connecting the wiring loom.

​The fuseboard, fed with 5 core cable [3phase] had to be moved to a safer location as goats, apparently, can be a bit disruptive. I also installed a 3 phase cut off switch that was within easy reach for extra safety measures. In a short space of time an impressive ramp and trough system had been built ready to milk many goats at once.
Picture
On completion, the system was tested to make sure that the motors worked in conjunction with the pump and suction hoses [apologies for the terminology, electrics and farming are two very different things]. We made sure the safety cut off worked, voila and the system was ready for the lady goats in no time.
Wishing Noah's Ark Farm all the very best with their increased milking facility.

For more information visit their Facebook page https://www.facebook.com/NoahsArkFarmBouin/
They produce a variety of quality farm reared free range meats and eggs all year round. Plus they are taking turkey orders for Christmas already!  

0 Comments
<<Previous

    Author

    These brief blogs are brought to you by Paul Wilkins of Paul Wilkins Electricien.

    Archives

    February 2023
    March 2020
    January 2020
    February 2018
    September 2017
    February 2017
    January 2017
    August 2016
    July 2016
    June 2016
    March 2016
    December 2015
    September 2015
    July 2015
    June 2015
    March 2015
    November 2014
    February 2014
    December 2013
    November 2013
    October 2013
    September 2013
    August 2013
    June 2013
    May 2013
    April 2013
    March 2013
    February 2013
    January 2013
    December 2012
    November 2012

    Categories

    All
    3Phase
    Appliances
    Customers
    Diagnostics
    Electric Heating
    Electricity
    Gites
    Homes In France
    Hot Tubs And Swimming Pools
    Leisure
    Lighting
    Miscellaneous
    Rewire
    Safe Electrics
    Safety
    Smoke Detection
    Ventilation
    Work I Have Done

    RSS Feed

Powered by Create your own unique website with customizable templates.