Round up of keeping homes electrically safe across Dept 79 and beyond

12/10/2015

4 Comments

 
Picture
Here's a quick review of some of the work that I have undertaken over the last few months. With a very mild and warm Autumn blending into November and December a lot of customers are seeking to make the most of the weather and keep me busy. A number of rewires have been done along with additional works.  All work done with pride and professionalism and to French Normes too!  

Chaignepain 79: continuation of rewire which finished in the Autumn

Château Garnier 86: complete rewire following on from new purchase

Chef Boutonne79: continuation of ongoing rewire plus upgrade to 3phase and splitting loads evenly

Cherigne 79: lighting – installation of downlights and radiators

Clussauis la Pommeraie 79: rewiring of kitchen to French Normes in readiness for new kitchen installation

Cognac 17: 3 phase board change and additional works

Fontenille 79: fuseboard change and updating installation plus electrical gates

Melleran 79: rewire as clients wanted electrics to be in compliant order before putting property on market

St Romain 86: additional works to include radiators and external lighting for decking area

Tillou 79: updating of current electrical system

Vancais 79: board change and additional works
​
​Vanzay 79: renovation of attic into bedrooms and updating current system



4 Comments

3 Phase - it's a balancing act

12/6/2015

11 Comments

 
Picture
It is quite common in older French property to find that the electrical system is supplied in 3 phase, as opposed to single phase.  

When called to quote on electrical work on french properties by new proprietors, I am often asked what is the difference and what does it mean? And more often than not, there are numerous common problems such as when the kettle is switched on the power cuts off or when the hoover is used the power trips. This is because small electrical items can draw a large amount of current. E.g. A kettle can draw around 8amps for the period that it is boiling.

A 3 phase system can work well if you have and use a small amount of electrical appliances or a large incoming supply. With single phase these problems are less likely.  3 phase is a balance of loads. 

For example, using an incoming supply of 60amps [60A], the supply is split into 3 x 20A. Old houses in France usually have outbuildings so having 3 phase means that the supply might be split as follows: 20A for the house, 20A for the barn and 20A for the workshop. Bearing in mind that many years ago there would have been less use of electrical items such as kettles, hoovers, radios, tumble dryers, washing machines. Therefore, very little tripping of power in the kitchen. If you have purchased a property today with 3 phase and plug in all of your appliances – you are very quickly going to over draw on the 20A. E.g. a washing machine may draw 10amps, your freezer may draw 4-6 amps, then when you put the kettle on, another 8amps could be drawn and click you exceed the 20A and the power trips out. With single phase you have 60A feeding the house, you have one large supply coming directly to your dwelling. So your appliances can be switched on with no problem of overload.

I have recently worked on a property which had to be reverted back to 3 phase purely because there was not enough power to the house. I.e. it needed 90Amps minimum which could not be provided by single phase. Therefore I have had to very carefully balance all 3 phases at 30A.
​
No phase can be exceeded, so a qualified electrician has to carefully balance the phases so that should all items be working at one time the current drawn will not overload any of the phases.   
11 Comments

    Author

    These brief blogs are brought to you by Paul Wilkins of Paul Wilkins Electricien.

    Archives

    March 2020
    January 2020
    February 2018
    September 2017
    February 2017
    January 2017
    August 2016
    July 2016
    June 2016
    March 2016
    December 2015
    September 2015
    July 2015
    June 2015
    March 2015
    November 2014
    February 2014
    December 2013
    November 2013
    October 2013
    September 2013
    August 2013
    June 2013
    May 2013
    April 2013
    March 2013
    February 2013
    January 2013
    December 2012
    November 2012

    Categories

    All
    3Phase
    Appliances
    Customers
    Diagnostics
    Electric Heating
    Electricity
    Gites
    Homes In France
    Hot Tubs And Swimming Pools
    Leisure
    Lighting
    Miscellaneous
    Rewire
    Safe Electrics
    Safety
    Smoke Detection
    Ventilation
    Work I Have Done

    RSS Feed

Powered by Create your own unique website with customizable templates.